GYC-PC261 Liquid-Cooled Energy Storage Cabinet 261kWh 125kW
GYC-PC261 is a 261kWh liquid-cooled outdoor energy storage cabinet for commercial and industrial applications. It uses 3.2V 314Ah LFP cells with a 728–923V battery operating range, 125kW rated power and IP55 battery-compartment protection. The integrated platform supports grid-connected and backup energy-storage applications, with the inverter available as an option.
Description
261kWh Liquid-Cooled Energy Storage Cabinet for C&I Projects
The GYC-PC261 is an outdoor liquid-cooled energy storage cabinet designed for commercial and industrial energy-storage applications. It integrates a 261kWh lithium iron phosphate battery system into a compact outdoor cabinet, with an inverter available as an optional configuration.
The battery system uses 3.2V 314Ah LFP cells in a 1P260S configuration, providing a battery operating-voltage range of 728V to 923V. With 125kW rated power and a maximum charge/discharge rate of 0.5C, the GYC-PC261 is suitable for commercial solar-plus-storage, peak shaving, backup power and distributed energy projects.
Key Features
- 261kWh integrated battery-system capacity
- 125kW rated power
- 3.2V 314Ah lithium iron phosphate cells
- 1P260S battery-system configuration
- 728V–923V battery operating-voltage range
- Maximum charge/discharge rate ≤0.5C
- Liquid cooling for battery thermal management
- IP55 protection for the battery compartment
- Operating ambient temperature from -30°C to +55°C, with derating above 45°C
- Maximum operating altitude up to 4000m, with derating above 2000m
- Temperature and smoke detection
- Aerosol fire protection at PACK and system level
- Water fire-protection provision
- Optional inverter configuration
Technical Specifications
| Product Model | GYC-PC261 |
|---|---|
| Cell Type | LFP 3.2V / 314Ah |
| Battery Configuration | 1P260S |
| Battery Voltage Range | 728V–923V |
| Battery Capacity | 261kWh |
| Charge / Discharge Rate | ≤0.5C |
| Rated Power | 125kW |
| Rated Grid Voltage | 3/N/PE, 220V/380V; 3/N/PE, 230V/400V |
| Rated Grid Frequency | 50/60Hz ±5Hz |
| Rated Grid Current | 189.9A |
| Grid / Off-Grid Switching Time | <10ms |
| Power Factor | >0.99; adjustable 0.8 leading to 0.8 lagging |
| AC Current Harmonic THDi | <3% at rated output power |
| Maximum PV String Power | 250kWp |
| Maximum PV Input Voltage | 1000V |
| Rated PV Input Voltage | 600V |
| MPPT Operating Voltage Range | 150–950V |
| Maximum MPPT Input Current | 10 × 42A |
| MPPT / Maximum Input Strings | 10 / 20 |
| Maximum System Efficiency | 90% |
| Battery Compartment Protection | IP55 |
| Cooling Method | Liquid Cooling |
| Operating Temperature | -30°C to +55°C; derating above 45°C |
| Operating Humidity | 0–95% RH |
| Maximum Operating Altitude | 4000m; derating above 2000m |
| Weight | Approx. 2.6t |
| Dimensions (W × D × H) | 1000 × 1340 × 2390mm, excluding inverter |
Specifications are based on the supplier catalog and should be reconfirmed for the selected project configuration before quotation.
Liquid Cooling for Battery Thermal Management
Thermal management becomes increasingly important in high-capacity commercial battery systems. The GYC-PC261 uses liquid cooling to manage battery operating temperatures across the cabinet and support operation in demanding outdoor environments.
The supplier specifies an allowable ambient operating-temperature range of -30°C to +55°C, with power derating above 45°C. For projects in hot, cold or temperature-variable markets, actual site conditions should be provided before final configuration.
Integrated Fire Protection and Safety Design
The supplier configuration includes temperature and smoke detection together with aerosol fire protection at PACK and system level and water fire-protection provision.
Final fire-protection configuration, local code requirements and project-specific safety requirements should be confirmed before ordering, particularly for commercial and industrial installations.
Typical Applications
- Commercial and industrial solar-plus-storage projects
- Commercial peak shaving and load shifting
- Industrial backup power
- Distributed energy-storage projects
- Commercial microgrids
- Renewable-energy self-consumption
- Projects requiring outdoor high-capacity battery storage
- Commercial facilities requiring grid-connected and backup operation
How to Select the Right C&I Energy Storage Configuration
1. Determine Required Energy Capacity
Start with the facility load profile rather than selecting the cabinet only by nominal kWh. Determine the daily load curve, peak-demand period, required backup duration and expected energy-shifting requirement.
2. Determine Required Power
Battery capacity and system power serve different functions. The GYC-PC261 provides 261kWh battery capacity with 125kW rated power. Confirm whether this power-to-energy ratio matches the intended peak-shaving, backup or solar self-consumption strategy.
3. Confirm Grid Conditions
Provide the project grid voltage, frequency, connection method and whether grid-connected, backup or combined operating modes are required.
4. Confirm Solar PV Requirements
For solar-plus-storage projects, provide the installed or planned PV capacity, PV string configuration and required operating strategy. The catalog lists a maximum PV string power of 250kWp for the relevant configuration.
5. Confirm Installation Conditions
Provide ambient temperature, altitude, available installation area, outdoor environmental conditions, maintenance access and applicable local electrical and fire-safety requirements.
GYC-PC261 vs Modular Battery Cabinets
The GYC-PC261 is intended for projects requiring a more integrated commercial energy-storage platform. Smaller modular battery cabinets may be more appropriate where lower storage capacity or a separate PCS architecture is preferred.
For lower-capacity outdoor battery-storage projects, view the BOC Low-Voltage Lithium Battery Outdoor Cabinet 15–96kWh.
Why Source C&I Energy Storage Through ORIDY ENERGY?
- Project-based battery capacity and power configuration support
- Battery, inverter/PCS and PV-system matching before quotation
- Supplier-side technical coordination
- Configuration comparison according to project requirements
- OEM/ODM coordination where applicable
- Export documentation and logistics coordination
- DDP and CIF shipping options according to destination and project conditions
Information Required for Quotation
For a more accurate GYC-PC261 configuration and quotation, please provide:
- Destination country
- Project type and application
- Required battery capacity in kWh
- Required system power in kW
- Facility load profile if available
- Grid voltage and frequency
- Existing or planned solar PV capacity
- Grid-connected / backup operating requirements
- Required backup duration
- Installation environment and ambient temperature
- Estimated quantity
- Required certifications and project documentation
- OEM/ODM requirements, if applicable
- Preferred trade term and delivery destination
Frequently Asked Questions
What is the battery capacity of the GYC-PC261?
The supplier catalog specifies a nominal battery-system capacity of 261kWh.
What is the rated power?
The catalog lists 125kW rated power for the GYC-PC261 configuration.
What battery cells are used?
The GYC-PC261 uses lithium iron phosphate cells specified as 3.2V / 314Ah in a 1P260S battery-system configuration.
What is the battery operating-voltage range?
The supplier catalog specifies a battery operating-voltage range of 728V to 923V.
Does the GYC-PC261 use liquid cooling?
Yes. The supplier identifies the GYC-PC261 as a liquid-cooled outdoor integrated cabinet.
Does the cabinet include an inverter?
The supplier catalog marks the inverter as optional. The required inverter or power-conversion configuration should therefore be confirmed according to the project before quotation.
Is the GYC-PC261 suitable for outdoor installation?
The product is specified as an outdoor integrated cabinet. The catalog lists IP55 protection for the battery compartment. Site conditions and local installation requirements should still be confirmed before deployment.
Request a GYC-PC261 Project Configuration & Quote
Send ORIDY ENERGY your project location, required kWh and kW, grid conditions, PV capacity, operating strategy and quantity. We can help review the required configuration and coordinate a project quotation with the supplier.